Appendix AXD Tools Test Reference 43
Video Controller Tests
The availability of video controller tests depends on the video controller installed in
the Xserve.
Test Estimated completion time Description
PCI-E 8 LinkWidth Verication 1 second Veries PCI link width is 8.
Framebuer Address as Data 2 minutes Tests the framebuer using
framebuer addresses as data.
AXD Mac OS X Tests
These tests are available if your Xserve is running AXD Mac OS X tools.
Startup Tests
These tests run automatically when you start up AXD Mac OS X tools.
SMBIOS tests check to see if bad memory was detected and mapped out at Xserve
startup. When the Xserve tests memory at start up, it automatically maps out bad
memory. Mac OS X doesn’t see this mapped out memory, so the non-SMBIOS memory
tests don’t test it. The SMBIOS test reports these mapped out DIMMS.
When an ECC error occurs, memory catches the problem and and xes it. When you
run other memory tests, the tests don’t realize an error has occurred. The ECC tests
detect these memory xes and report them.
Test Estimated completion time Description
Hardware Existence 1 second Compares a table of sensors and
fans with what is connected to
the logic board. If a sensor or
fan isn’t found, an error occurs.
All sensors, fans, and hard
drives found can be individually
tested using sensor, fan, hard
drive tests.
SMBIOS Self-Test 1 second Checks the SMBIOS tables for
32-bit errors (type 18) and 64-
bit errors (type 33). Also veries
that the mapped-in DIMM size
is appropriate for the slot it’s
inserted into. If there’s a size
mismatch, an error occurs.
ECC Error Count 1 second Reports the number of
ECC errors, and then resets
the count.