2 -
Xserve RAID Take Apart
Hard Drive Module
Hard Drive Module
Xserve RAID includes fourteen hard drive bays at the front of the system. Drives come as
modules attached to carriers; they are removed from or installed in the system as a unit.
Note:
Blank drive carriers, which may fill some of the hard drive bays, follow the same
take-apart procedure as hard drives. If you are replacing a blank carrier with a drive
module, instruct the system’s administrator to keep the blank for possible future use. Blank
carriers must be installed in all empty bays to maintain proper airflow through the system.
Tools
No tools are required for this procedure.
Preliminary Steps
Before you begin, make sure the drives are in the unlocked position. No other preliminary
steps are required. You can replace or install hard drives while Xserve RAID is running;
you do not need to shut down or open the unit first.
Note:
There are two LED indicators on the front of each drive.
The right LED shows drive status: a green light indicates the drive is good; a yellow or
red light indicates the drive should be replaced or removed and reinserted.
The left LED shows drive activity: when the light is blinking, the system is reading from
or writing to the drive. To avoid losing data, never remove a drive when the lower LED
is blinking.
WARNING:
Drives must be in the unlocked position before you attempt to remove a drive.
If the drives are locked, pulling on the drive to remove it could damage the drive handle.
Part Location